Control Panel Connection Table
The table below shows connection details for various alarm control panels:
Trigger Inputs
Control Panel
1
Fire
2
PA
3
Intruder
Trigger
Polarity
12V
0V
ADE Accenta 6 N/A N/A B -ve 13V+ 13V-
ADE Concept 6 N/A N/A B -ve 13V+ 13V-
ADE Optima 6 N/A N/A B -ve 13V+ 13V-
ADE
Optima XM
N/A N/A B -ve 13V+ 13V-
C&K 800L N/A N/A S- -ve Aux + Aux -
CQR Premier 9 FA* PA IA +ve Aux
12V
Aux
0V
DA Abacus 6 N/A N/A Bell -ve +12V -0V
DA Abacus 8 N/A N/A Bell -ve +12V -0V
Gardtec 500
Series
N/A N/A Bell- -ve 12V 0V
Gardtec 800
Series
D1* PA 12Hr -ve 12V 0V
Menvier
TS400/410
Cct 4 Cct5 ALM -ve Aux + Aux -
Menvier TS
Range
Comm.
1
Comm.
2
Comm. 3 -ve Aux + Aux -
Pyronix Octagon N/A PA ALM -ve Aux + Aux -
Pyronix
Conqueror
N/A N/A BA -ve Aux + Aux -
Scantronic 9448 N/A COM 2 COM 3 -ve 12V 0V
Scantronic 9X5X
Series
Pin 1 Pin 2 Pin 3 -ve Pin 9 Pin 10
Texecom Veritas
8/R8/
N/A N/A B -ve Aux + Aux -
Texecom Veritas
R8 Plus
Com1 Com2 Com3 -ve Aux + Aux -
Texecom Veritas
Excel
Com1 Com2 Com3 -ve Aux + Aux -
Texecom Premier
48/88/168
Digi1* Digi2* Digi3* -ve Aux + Aux -
*Control panel output may require programming to the correct
function.